Quick Connect/Disconnect Kit for Scepter Jerry Cans Instructions
Quick Connect / Disconnect Kit for Scepter Jerry Can Adapter
Important: This Quick Connect kit is for the heater side and must be used together with the Jerry Can Adapter Kit.
Installation Instructions
1. Install the Female Quick Connect on the Heater
- Unscrew the metal retaining nut from the female quick connect fitting.
- Insert the female connector through the hole on the front panel of the heater.
- Thread the metal nut back onto the connector from the inside and tighten until snug (do not overtighten).
2. Connect the Heater Fuel Line
- Disconnect the existing fuel line between the Polar Pal fuel tank and the fuel pump.
- Slide the provided hose clamps onto the new fuel line section.
- Push one end of the fuel line onto the fuel pump inlet and the other end onto the barb of the female quick connect.
- Tighten the hose clamps securely.
3. Connect the Jerry Can Adapter Line
- Slide the provided hose clamps onto the Jerry Can Adapter fuel line.
- Push the fuel line onto the male quick connect fitting and tighten the clamps.
- Insert the male quick connect into the female quick connect until it clicks into place.
The quick connect system is now ready for use.
⚠️ WARNING – Fuel Pump Priming
- Ensure the fuel lines are fully primed and contain little to no air bubbles before starting the heater.
- Use the heater’s priming function no more than once when the system is dry.
- Repeated dry priming can permanently damage the fuel pump.